The ACS355 machinery drive, 0.37 to 22 kW, left new-part sales in 2025; the ACS380 is ABB's direct successor, and the ACS580 is the route for machines that only need general-purpose speed control.
The short answer
Convert to an ACS380 when the machine uses the drive's built-in sequence programming or an F-series fieldbus adapter. Convert to an ACS580 when it is a fan, pump or simple conveyor with no logic inside the drive. Keep tested ACS355 units for machines due to be retired.
- 0.37-22 kWthe ACS355 range
- 3routes after end of sale
- 33-36STO terminals that move
When it fits, and when it does not
An ACS355 that fails at two in the morning is not a selection problem, it is a stock problem. For a machine with two years left, the honest answer is a tested spare, not a conversion project: the conversion costs more and adds commissioning risk to a line that is leaving.
For everything else, ask what the old drive did that a general-purpose drive cannot. Usually one of three things: sequence programming living inside the drive, an F-series fieldbus adapter with no equivalent slot on the new platform, or a cabinet with no spare depth for a taller frame.
| If the machine | Route | Why |
|---|---|---|
| Is due to be retired within two years | Tested ACS355 spare | Conversion cost and commissioning risk buy nothing on a line that is leaving |
| Runs its cycle with sequence programming in group 84 | ACS380 | Adaptive programming keeps the logic inside the drive instead of adding a small PLC |
| Talks PROFINET through a FENA adapter | ACS380 with the matching BCON variant | F-series adapters do not carry over; the fieldbus becomes part of the drive order |
| Is a pump, fan or simple conveyor with no internal logic | ACS580 | More I/O and a wider power range at a lower cost per kW |
| Needs closed-loop control or positioning | ACS880 | Encoder interfaces on a motion-capable platform; neither the 380 nor the 580 has one |
| Runs 22 kW at 150% overload | Size on heavy-duty current, not on kW | ACS355 ratings are heavy duty by default; the new tables are not |
Two routes end in a part we stock and one ends in an order placed with ABB. All three are legitimate; the expensive mistake is choosing on kW alone.
Key differences
ACS355 and ACS380 share the machinery intent, the DIN-rail mounting and ABB's common parameter naming. They do not share a terminal strip, an option slot or a parameter file, and the frame is taller. This is what to check before the old drive comes off the wall.
| Item | ACS355 (existing) | ACS380 (successor) | ACS580 (general purpose) |
|---|---|---|---|
| Power range | 0.37 to 22 kW | 0.25 to 22 kW | 0.75 to 500 kW |
| Drive class | Machinery drive | Machinery drive | General purpose |
| Datasheet default rating | Heavy duty | Normal duty column first | Normal and heavy duty columns |
| Standard I/O | 5 DI, 1 AI, 1 AO, 1 relay | 4 DI, 2 AI, 1 AO, 1 DO, 1 relay | 6 DI, 2 AI, 2 AO, 3 relay |
| STO terminals | 33, 34, 35, 36 | S1, S2, SGND | Separate STO terminal block |
| Fieldbus | F-series adapters: FENA, FPBA, FMBA | BCON, BIO and BAPO modules | FPNO or FPBA in the single slot |
| Programming | Sequence programming, group 84 | Adaptive programming | Adaptive programming |
| Frame R1 height | About 169 mm | About 223 mm | Taller again |
| Best for | Machines with internal logic | Machines with internal logic | Pumps, fans, conveyors |
Frame dimensions change with the fieldbus module fitted and vary by variant. Measure the cabinet before ordering, not after the drive lands on the bench.
What to specify, in order
Read the rating column the old drive was sold under
ACS355 datasheets list heavy-duty current as the default figure; ACS380 and ACS580 lead with normal duty. Take the motor nameplate current, apply the overload the machine needs, then choose the frame from the heavy-duty column. A same-kW swap can land thirty percent short on current.
Map the terminals on paper before the drive arrives
STO moves from terminals 33 to 36 to S1, S2 and SGND. DI5 disappears, the relay output changes number, and the digital inputs are assigned differently by default. Draw the new strip, mark the wires, then terminate once.
Port the logic deliberately, not from memory
Sequence programming in group 84 has no line-by-line equivalent; the new drives use adaptive programming blocks. If the old program had more than a dozen steps, budget a day with Drive Composer and a test motor rather than finding the gaps on the machine.
Check the cabinet depth and the door
The R1 frame grows from roughly 169 mm to 223 mm in height and the depth changes with it. In a shallow cabinet the drive fits the DIN rail and not the closed door, which is a panel modification discovered at installation.
Keep one tested ACS355 per critical machine
For a line that is not converting this year, a tested spare is the cheapest risk control available: it removes a four-week sourcing exercise from a breakdown. We test and record each unit before it ships and state condition on the quote.
Common pitfalls
Matching kW instead of current
A 2.2 kW ACS355 is a heavy-duty 5.6 A device. The ACS380 frame that matches it in the heavy-duty column is not the frame that matches it on the normal-duty kW line, and the gap runs to thirty percent.
Asymmetric STO wiring leaves the drive dead
On the ACS380 both safe inputs have to be wired and bridged correctly. A single-channel bridge produces a permanent STO active fault that reads like a failed drive and is really a terminal mistake.
DriveWindow files cannot be opened by the new tool
.dwg and .dp5 backups are not readable by Drive Composer. Parameters have to be transcribed group by group from a printout, which is why the old backup should be printed before the drive is removed.
Option modules do not migrate
Encoder, fieldbus and I/O modules from the F-series are physically incompatible with the new slots. Every module in the old drive has to be re-specified, and each one adds lead time.
IP66 is a different drive, not a seal
The IP66 variant has different dimensions and cable entries. An IP20 unit with a cover is not IP66, and water ingress is excluded from the warranty for exactly this reason.
Questions we get on the quote desk
Can I still buy a new ACS355?
Is an ACS580 a valid replacement for an ACS355?
Do I have to change the motor cable?
What replaces an ACSM1 motion drive?
The models this guide names
Where these models sit in the catalog
-
ACS355-03E-08A8-4
Quote on request
ACS355, 8.8 A, 400 V. The frame found in most OEM panels; we stock tested units as spares.
Request a price -
ACS580-01-05A7-4
In the catalog
ABB
ACS580, 5.7 A, 400 V. The general-purpose route for a small conveyor or fan.
Open the part -
ACS580-01-026A-4
Quote on request
ACS580, 26 A, 400 V. For larger pump and fan conversions.